Latest NAStorage
5.60 Firmware
Latest NAStorage 84xx 2.60 Firmware
Above 2TB NAStorage 84xx / 44xx 3.05 Firmware

ER2510FS - 1U Fibre External RAID Head <<<Go Back
  • Multiple target IDs and 1024 LUNs for host connection
  • Up to 64TB capacity per Logical Drive (LD) (OS dependent)
  • Battery-backed cache memory; addressable from 128MB to 1GB per controller
  • Intelligent Drive Handling
  • Optimization per array
    Configuration Models I/O Channels
    Single ER 2510FS-4S 4 Fibre
    Single ER 2510FS-6S 6 Fibre
    Dual-Single ER 2510FS-4D 8 Fibre
    Dual-Single ER 2510FS-6D 12 Fibre
    Redundant ER 2510FS-4RH 4 Fibre
    Redundant ER 2510FS-6RH 6 Fibre
    Specifications
  • Enclosure:  
    Form Factors 44mm(H) x 427mm(W) x 537mm(D, front ears included); front and rear mounted in 19" rack
    Hot-swap components Dual power, RAID controller canisters, cooling modules, IO node modules, battery units, management interface modules
    Controller Specifications:
    CPU 64-bit, 400MHz PowerPC CPU with 32KB/ I/O cache and 256KB L2 cache embedded
    Cache Memory 128/256/512MB/1GB SDRAM w/ECC
    Flash 4 MB
    Hardware XOR Yes
    Proprietary ASICs Dual 64-bit chipsets
    Memory bandwidth 1066MB/s (64-bit, 133MHz)
    Transparent failover/failback Dual-active, host-transparent operation
    Fibre Channel Specifications:
    Host/drive interface FC-2G Fibre channel
    Number of channels 4 or 6 (by single or dual-redundant controllers), 8 or 12 (dual-single controllers). All channels are host or drive configurable
    Supported topologies SAN ready: FC-AL, point-to-point, or switched fabric
    RAID Fault-Tolerance and Flexibility:
    Supported RAID levels 0, 1, (0+1), 3, 5, 10, 30, 50, NRAID, and JBOD
    Logical drives 128 ( up to 64 partitions per logical drive)
    Clustering Persistent reservation support
    RCC over Fibre (inter-controller communications) Yes,
    1. Over dedicated comm. loops.
    2. Over drive loops
    Drive roaming during
    power-off
    Yes
    Automatic rebuild of
    hot-spare
    Yes
    Variable stripe size Yes, configurable per logical drive
    Configurable priority of rebuild, parity regeneration, media scan, etc.
    Maximum no. of LUNs 32 per ID, up to 1024 per controller
    SCSI pass-through
    commands
    Yes, transparent disk drive support
    Online RAID
    expansion
    Yes,
    1. By adding drives.
    2. By replacing drives with drives of larger capacity
    Synchronized cache
    between controllers
    Yes, along with controller configuration data
    Battery Li-ion cells in hot-swappable modules
    Write-through/
    Write-back
    Adjustable per logical drive
    Online upgrade Rolling firmware upgrade for dual-active controllers
    Management:
    In-band Yes
    Out-of-band
    1. Firmware-embedded utility over RS-232C
    2. Java-based RAIDWatch manager over an integrated Ethernet port
    Management software RAIDWatch: Java-based, OS independent; sub-modules include Event Monitor, a monitoring utility running independently; and NPC, a notifier via email, LAN broadcast, and SNMP traps
    The information is subject to change without any notice

     

       


       ©2009 .StoreTech Systems Inc.All Rights Reserved. Privacy Policy