Latest NAStorage
5.60 Firmware
Latest NAStorage 84xx 2.60 Firmware
Above 2TB NAStorage 84xx / 44xx 3.05 Firmware

A16U-G2430 <<<Go Back
  • (2) SCSI-320 host channels; transfer rate up to 320MBps per channel.
  • RoHS-compliant
  • Accommodates sixteen (16), 3Gbps, SATA-II disk drives.
  • ASIC400 architecture with hardware RAID6.
  • Market leading I/O performance
  • Sustained RAID5 Read/Write at 566/484 MB/sec.
  • Sustained RAID6 Read/Write at 566/426 MB/sec.
  • Up to 2GB DDR memory, ECC protected.
  • Hot-swappable, life expectancy-aware battery backup.
  • Online expansion, array roaming, and centralized management.
  • RAID
  • Multiple arrays each with an independent RAID level
  • Dedicated, enclosure-specific, or global hot spares.
  • RAID levels: RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
  • Online RAID level migration
  • Online expansion by:
  • Adding new drives
  • Copying and replacing drives with drives of larger capacity
  • Automatic background rebuilds.
  • Independent array stripe size and write policy
  • Intelligent drive handling
  • Degraded mode: skips irreparable blocks to continue rebuild
  • Normal: data-block verification and repair
  • Intelligent Drive Handling
    If two bad blocks occur on two member drives of an array, the integrity of the stored data is endangered. Media Scan, Infortrend's innovative intelligent drive handling function, retrieves data from the damaged sectors. Media Scan handles low quality drives in both the degraded mode and during the rebuild process. For additional data security, other intelligent drive management features include the transparent resetting of hung hard drives, power-failure management, and bad-drive handling during LD expansion.

    System Components

    Single RAID controller configuration provides full-featured RAID functionality

    • Backplane-based, cableless design
    • Single-controller configuration provides full-range RAID functionalities
    • Two (2) hot-swappable, redundant, 530W power supply units (PSUs)
    • Two (2) redundant, dual thermal fans, cooling modules.
    • One (1) optional BBU
    • Sixteen (16) hot-swappable drive trays
    • LCD keypad panel
    Management

    Firmware-embedded utility via LCD keypad or RS-232C terminal
    10/100BaseT Ethernet for out-of-band management
    Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
    Telnet access via onboard Ethernet port
    Java-based RAIDWatch® Manager Graphical user interface

    • Local/remote management; in-band or out-of-band via TCP/IP
    • Centralized management of multiple subsystems from one management computer
    • A variety of event notification methods via the Configuration Client sub-module: email, fax, LAN broadcast, SNMP traps, MSN messenger, ICQ, and SMS short messages Secure link over SSL
    Drive Interface
    Sixteen (16) 3.0Gbps SATA-II, hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch SATA-I, SATA-II.
    Automatic bad-sector reassignment
    Dedicated bandwidth to each connected drive
    Host Interface
    Two (2) SCSI-320 through four (4) VHDCI 68-pin SCSI ports; SCSI-160 backward compatible
    Concurrent I/O commands
    Tagged command queuing up to 256
    Variable stripe size per logical drive
    Optimization setting for random or sequential I/Os
    SNMP agent support

    SNMP trap event notification with plain-text event message (no MIB file required)
    SNMP V2.0 MIB file support with get-and-set commands

    Indicators

    Onboard alarm is triggered when one of the following modules fails:
    RAID controller module
    Cooling module
    Power supply unit
    Hard drive

    Notification Processing Center (NPC) for real-time event notification over email, LAN broadcast, or SNMP traps
    Module status LED indicators:
    Two (2) per drive tray
    Two (2) per cooling module
    One (1) per power supply unit
    Three (3) per LCD panel
    Six (6) per RAID controller module

    Module failure alert through bus

    Auto switch cache policy and Auto shutdown
    When a RAID controller detects conditions exceeding preset thresholds, the following actions will be exerted to protect the hardware:

  • Cached data is automatically flushed and the array’s caching mode switches from write-back to write-through mode.
  • If conditions persist past the preset period of time, auto shutdown of the controller will commence.

    All thresholds associated with this mechanism are user configurable and, once a subsystem manager restores the normal operating conditions, the caching mode changes from write-through back to write-back mode.

  • Physical/Electrical
    Four (4) ports in two (2) dual-stacked VHDCI SCSI connectors
    Two (2) COM ports (38400, n, 8, 1)
    One (1) 10/100BaseT Ethernet port
    Power supply
    Two (2) redundant hot-swappable power supplies with PFC
    Input: 100VAC at 10A, 240VAC at 5A with PFC (auto-switching)
    47 ~ 63Hz
    Output: (Maximum output: 460 Watts)
    +12.0V 32A max.
    + 5.0V 32A max.
    + 3.3V 30A max.
    Dimensions: 248.9(D) x 128(W) x 82.1(H) mm
    Cooling fan
    Two (2) redundant dual-fan cooling modules
    Maximum air flow: High speed: 31.78 DFM
    Low speed: 20.13 CFM
    Dimensions: 263.7(D) x 123.2(W) x 36.4(H) mm

    Environmental Specifications
    Operating temperature: 5° to 40°C
    Non-operating temperature: -20° to 60°C
    Relative humidity: 5 ~ 95%, non-condensing
    Operating altitude: Operating: 0 ~ 10,000 ft
    Dimensions:
    Chassis without handles: 445(W) x 130(H) x 488.2(D) mm
    Chassis with handles: 482.6(W) x 131(H) x 504.3(D) mm
    Package: 423H x 567W x 772D mm
    System weight (w/o drives):
    Net weight: 28.5 kg
    Gross weight: 30.0 kg


       ©2009 .StoreTech Systems Inc.All Rights Reserved. Privacy Policy