- Full-featured RAID functionality with
two (2) SCSI-320 host channels; transfer rate up to
320MBps each
- Up to 12TB of storage capacity
- Accommodates twenty-four (24) SATA
II hard drives, backward compatible with SATA I drives
- Hardware XOR engine by dedicated ASIC266
chipsets
- Dual-speed cooling modules to reduce
system noise
- Backplane-based, cableless, modular
enclosure
|
| RAID |
Multiple
arrays configurable with dedicated or global hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50,
NRAID and JBOD
Online expansion by
Adding new drives
Copying and replacing drives with drives
of larger capacity
Automatic background rebuild
Configurable stripe size and write policy per array
|
| Intelligent
Drive Handling |
If two bad
blocks occur on two member drives of an array, the integrity
of the stored data is endangered. Media Scan, Infortrend's
innovative intelligent drive handling function, retrieves
data from the damaged sectors. Media Scan handles low quality
drives in both the degraded mode and during the rebuild
process. For additional data security, other intelligent
drive management features include the transparent resetting
of hung hard drives, power-failure management, and bad-drive
handling during LD expansion.
|
| System
Components |
|
Single RAID controller configuration
provides full-featured RAID functionality
- One (1) 4U enclosure
- One (1) RAID controller module
- One (1) 256MB DDR RAM DIMM module preinstalled
on the controller module; system supports 256MB to 2GB
capacity DIMM modules
- Three (3, N+1) hot-swappable, redundant,
405W power supply units
- Twenty-four (24) hot-swappable drive
trays
- Two (2) hot-swappable, redundant cooling
modules
- Two (2) forearm front handle
|
| Management |
|
Firmware-embedded utility via LCD keypad
or RS-232C terminal
10/100BaseT Ethernet for out-of-band management
Two (2) COM ports for local access to firmware-embedded
utility and UPS connectivity
Telnet access via onboard Ethernet port
Java-based RAIDWatch® Manager Graphical user interface
- Local/remote management; in-band or
out-of-band via TCP/IP
- Centralized management of multiple
subsystems from one management computer
- A variety of event notification methods
via the Configuration Client sub-module: email, fax,
LAN broadcast, SNMP traps, MSN messenger, ICQ, and SMS
short messages Secure link over SSL
|
| Drive
Interface |
Twenty-four
(24) hot-swappable 3Gbps SATA II drive trays that accommodate
1-inch pitch SATA II or SATA I disk drives
Native Command Queuing (NCQ) support
Dedicated bandwidth to each connected drive
Automatic bad sector reassignment |
| Host
Interface |
Two (2)
SCSI-320 host channels interfaced through two (2) dual-stacked
VHDCIs
Tagged command queuing up to 256
Host-side ordered tag support |
| SNMP
agent support |
|
SNMP trap event notification with plain-text
event message (no MIB file required)
SNMP V2.0 MIB file support with get-and-set commands
|
| Indicators |
|
Onboard alarm is triggered when one of
the following modules fails:
RAID controller module
Cooling module
Power supply unit
Hard drive
Notification Processing Center (NPC) for real-time event
notification over email, LAN broadcast, or SNMP traps
Module status LED indicators:
Two (2) per drive tray
Two (2) per cooling module
One (1) per power supply unit
Three (3) per LCD panel
Six (6) per RAID controller module
Module failure alert through bus
|
| Auto
switch cache policy and Auto shutdown |
When a RAID
controller detects conditions exceeding preset thresholds,
the following actions will be exerted to protect the hardware:
Cached data is automatically flushed
and the arrays caching mode switches from write-back
to write-through mode.
If conditions persist past the preset
period of time, auto shutdown of the controller will commence.
All thresholds associated with this mechanism are user
configurable and, once a subsystem manager restores the
normal operating conditions, the caching mode changes
from write-through back to write-back mode.
|
| Physical/Electrical
|
Four (4)
68-pin VHDCIs in dual-stacked configurations
Two (2) COM ports for RS-232C terminal and UPS connection
(38400, n, 8, 1)
One (1) 10/100BaseT Ethernet port |
| Power
supply |
Three (3)
redundant, hot-swappable power supplies with PFC
Nominal Power 405W
DC Output +3.3V: min. 0.5A, max. 20A
+5V: min. 2.5A, max. 36A
+12V: min. 1A, max. 24A
+5V SB: min. 0A, max. 0.5A
Input Frequency 47 to 63Hz
AC Input 90VAC @ 8AC ?264VAC @ 4AC with PFC |
| Cooling
fan |
Two (2)
redundant cooling fan modules
Environmental Specification
Humidity 5% to 95% (non condensing ?operating and non-operating)
Temperature Operating : 0º to 40ºC
Non-operating : -20º to 60ºC
Altitude Operating : sea level to 12,000 ft
Non-operating : sea level to 20,000 ft |
| Dimensions: |
Chassis
without handles: 445W x 174.4H x 498D mm (17.5 x 6.87 x
19.6 inches)
Chassis with handles 447W x 174.4H x 514D mm (17.6 x 6.87
x 20.2 inches)
Package: 590W x 480H x 700D mm |
| System
weight (w/o drives): |
Net weight:
36.5kg
Gross weight: 39.6kg |