Hardware RAID5 & RAID6 parity computation
Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
RAID Migration
Configurable stripe size and write policy per array
Multiple Global, Dedicated, & Enclosure-specific hot-spares
Intelligent Drive Handling:
Intelligent Drive Handling: In degraded mode: skips irreparable
blocks to continue rebuild
In normal operation: data-block verification and repair
Infortrend Smart Technologies
Derived from more than ten years experience in RAID storage
design, Infortrend's innovative firmware delivers Smart technologies
that provide enhanced storage solutions for every customer
environment, from small organizations to large enterprises.
These technologies enhance I/O processing, drive handling,
and system management.
IOSmart
IOSmart allows for the flexible configuration of logical drives,
logical volumes and logical partitions and ensures instant
RAID availability via background logical drive initialization.
Fibre loops' load balancing is provided within the subsystem.
The firmware's embedded intelligent algorithms, such as Adaptive
Write Policy and Guaranteed Latency I/O, improve sequential
write performance and ensure the fast and continuous flow
of data.
DrvSmart
The DrvSmart utility provides an easy way to store data while
keeping it safe. One of the main DrvSmart functions, Media
Scan, retrieves data from degraded or damaged hard drives
and handles low quality drives in both the degraded mode and
during the rebuild process. Other DrvSmart features include
disk cloning, drive roaming, SMART, transparent resetting
of non-responsive hard drives, and RAID parity update tracking
and recovery.
SysSmart
In addition to RAID protection for the disk drives, Infortrend
has introduced Auto Data Protection Mechanisms. These special
SysSmart firmware functions ensure data safety by automatically
switching to write-through data caching when abnormal subsystem
conditions are detected such as a PSU/cooling module failure,
low BBU or UPS battery charge, etc.
By using the firmware to monitor and control
the enclosure's dual-speed fans, the fan rotation speed is
raised to a higher level when critical conditions are detected,
e.g., a PSU or fan failure. Fan speed returns to the lower
setting when normal operating status is restored.
The ES F16F-R/S4031 can be monitored by variety
of utilities and approaches. I2C internal serial bus, SAF-TE,
and SES are seamlessly integrated into the comprehensive Java-based
GUI RAIDWatch Manager. Component status, voltage and temperature
readings, and system events are instantly revealed through
the manager's graphical interface.
|