The Magnum 448 combines high capacity and performance
in small 4U form factor.
Magnum 448 (LTO) Tape Library is redefining
the term tape library by offering the most scalable, affordable
and user-friendly tape library SMB and departmental users can
buy. It easily scales 'on demand' from a 1x48 to a 4x48 tape
library, with a choice of up to four half-high LTO-2 drives
or up to two full-high LTO-3 or LTO-4 drives. It offers up to
76.8 TB of compressed data storage all in a space-saving
4U form factor
Features
and Benefits
- High density with up to 76.8 TB compressed
data in 4U
- Performance up to 864 GB/Hr (compressed)
- Easily scales to offer performance on demand
with additional drives and drive upgrades
- Two LTO-3 or LTO-4 FH drive or Four LTO-2
or LTO-3 HH drives
- Offers SCSI and Native Fibre Channel connectivity
- Write Once Read Many (WORM) support for regulatory
compliance
- Easy to repair, upgrade or exchange
- 3 years factory warranty
Magnum448 has a host
of management and maintenance features, ensuring minimized down-time
and ease of management. Using the browser based remote management
interface, administrators can remotely monitor, control, configure
and diagnose the T24 via the Internet from anywhere in the world.
The T24 can automatically send an email notification if something
is wrong with the library, and it supports SNMP which
will immediately send information on any error situation that
occurs to the host.
All these features make the Magnum 448 the midrange
tape library of choice.
|
Capacity
Native/Compressed
|
Transfer
rate
Native/Compressed
|
|
With LTO-2: 9.6TB/19.2TB
With LTO-3: 19.2TB/38.4 TB
With LTO-4: 38.4TB/76.8 TB
|
With LTO-2: 86GB/346GB/hr
With HH LTO-3: 216GB/432GB/
With LTO-3: 288GB/576GB/hr
With LTO-4: 432GB/864GB/hr
|
|
Dimensions (LxWxD)
|
Form
Factor
|
|
77.54 x 44.63 x
17.65 centimeters
|
4U
|
|
Reliability
|
Tape Drive Mean Time Between Failures
(MTBF): >250,000 Mean time to repair: < 20 minutes
Non-disruptive serviceability: drive FRU, no disconnection
of interface cables required, Ethernet and serial
ports for diagnostics and reporting |
|
Environment
|
Operating temperature:10°C to
40°C (50°F to 104°F)
Nonoperating temperature: -40°C to 65°C
(14°F to 149°F)
Relative humidity, noncondensing,operating: 20%
to 80%Relative humidity, noncondensing, non-operating:
10% to 90%
|
|
Power
|
Voltage: 100 to 240 VAC, 50 to 60 Hz
Library (maximum operating):139 Watts RMS
Auto-switching power supply |
|
Software Compatibility
|
Compatible with all major backup applications
and operating systems.
|
|
|